DFM 170
|
|
|
|
|
|
|
|
|
|
FOR ALL INDUSTRIAL USES
• Graduated measuring ranges according to DIN.
• Graduated tubes.
• Indicator accuracy according to VDI/VDE 3513.
• Hermetically sealed, connected with o-rings.
• Vertical installation
TECHNICAL FEATURES
- Tube material: ___________________________ transparent u-PVC
- Float material: ________________________________________ PVDF
- Connections: _____________________ PVC DN15 d20 to be glue
- Max Pressure: _________________________________ PN10 at 20°C
- Max Temperature: _____________________________________ 60°C
- Min Temperature: ____________________________________ -20°C
- Pressure drop H2O at 20°C: _______________________ 2,5 m bar
- Weight: ______________________________________________ 96 g
CODES AND RANGE
- 47504: _____________________________________ from 5 to 50 l/h
- 47505: ___________________________________ from 15 to 150 l/h
- 47506: ___________________________________ from 25 to 250 l/h
- 47507: ___________________________________ from 40 to 400 l/h |
|
|
|
|
|
|
|
|